03/10 Rev. 5.04-04 SERVICE MANUAL Service Mechanics
64-xx – 64-xx Dispenser
18
Disassembly
1. Turn the threaded rod by the hexagonal
head out of the cap (1) and pull it out of
the ribbon mandrel.
2. Remove cap (1), spacer ring, spring (2)
shim rings, timing disc (3) and brake
disc (4).
3. Remove the lock washer (7) from the
brake lever. Unmount the brake rod (8)
from the brake lever. Remove the brake
lever (5).
4. Loosen both set screws (9) at the stop
disc (6). Remove the stop disc.
5. Remove the shim rings.
6. Push the ribbon mandrel through to the
opposite site.
If necessary, force the ribbon mandrel
out by tapping it lightly with the plastic
hammer.
1
2
3
4
5
6
7
8
9
6