03/10 Rev. 5.04-04 SERVICE MANUAL Service Mechanics
64-xx – 64-xx Dispenser
39
Material end sensor
The material end sensor detects the absence of material, thereby
protecting important components (e. g. thermal bar). The fault is displayed
and the device is stopped.
Disassembly/ ass. The material end sensor sits in the inner material guide of the device. The
sensor is stuck to the guide and can only be exchanged as an assembly
unit.
1. Remove the rear hood.
2. Detach the material end photoelectric switch at the cable tree (marked "M").
3. Remove the material guide.
4. Pull the material end photoelectric switch cable through the recess in the
cast plate.
For details about disassembling/assembling the inner material guide see
chapter Material guide on page 38.