62
6OPERATIONAL FAILURES
6.1 STATUS MESSAGES
ALS
20x
256
5145 Rewinder full This error can only occur if the
end of a new label roll was glued
on to backing paper that had
already been wound onto the
rewinder.
– The maximum permitted diameter
(205 mm) for the rewinder roll has
been reached.
Remove the rewound backing paper
Press the key to confirm the
error message.
5147 Tandemsynch.init This message can only appear
during tandem operation.
– Communication between the master
and slave machines is not
functioning.
Check, if the slave machine had
been switched on before the master
machine - if not, repeat the switching
on in the correct order (first slave,
then master).
Check, if both machines are
connected with the tandem interface
cable - if not, connect them. For
detailed information, contact a
service technician.
5152 Winding direct. The backing paper end is not correctly
attached to the rewinder mandrel.
Attach the backing paper web to the
rewinding mandrel as described in
chap. “Fastening the label roll to the
rewinder” auf Seite 44.
5200 Home position This message may appear when
operating the applicator. The
applicator did not reach its home
position (upper end position)
within the intended time-frame.
– Applicator operation set, but no
applicator available.
– The applicator is stuck.
– Compressed air applicator:
Compressed air supply interrupted or
switched off.
– Cable not correctly connected.
Set SIGNAL INTERFACE > Interface mode
to „PLC signals“.
Remove any obstructions
Check compressed air connection
and reconnect correctly if necessary.
Check cable and connect correctly if
necessary.
5201 Touch down The applicator lower end position
(Touch Down) was not reached in time.
6002 New prog. vers. New firmware has been loaded. This is a
message from the labeller that new
firmware is available.
Press the Online button to confirm.
– All parameters are reset to their
factory settings.
6030 New parameters New firmware was loaded with the result
that new functions have been added to
the menu.
Press the Online button to confirm.
– Automatic reset is performed.
– All parameters are reset to their
factory settings.
Status Status text Cause Action to take
[68] List of error messages