03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP5.4 Gen II – AP5.6
39
Printer ID No.
AP5.4 AP5.6
Printer identification number
Determines the identification number of the printer. In such a way, the printer
can be addressed by the Easy Plug command #!An (n=printer ID).
The use of ID numbers is in particular reasonable for data transfer by RS422/
485 interface, if several printers are connected by one data line. Each of the
connected printers then only incorporates the data mapped to him by #!An
command.
xx Setting range: 0 to 31; Unit interval: 1
Spooler size
AP5.4 AP5.6
The memory capacity of the printer buffer can be set according to the require-
ments of each customer.
xxx Kbyte Unit interval: 16-2048kBytes; step width: 16kBytes; default setting:
64 kBytes
Offline mode
AP5.4 AP5.6
Interf. disabled Easy-Plug commands are not accepted, while the machine is in offline mode
(default setting).
Interf. enabled Easy-Plug commands are accepted in offline mode.
Interface delay
AP5.4 AP5.6
After switching from online to offline mode, the printer interface is deactivat-
ed. This parameter offers a setable delay time before deactivating the inter-
face.
xxxxms Setting range: 0-1000; Unit interval: 100; Default setting: 0