03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP5.4 Gen II – AP5.6
42
Stop bits
AP5.4 AP5.6
¯ With mounted and connected I/O board only.
P See parameter Stop bits on page 45.
Data synch.
AP5.4 AP5.6
¯ With mounted and connected I/O board only.
P See parameter Data synch. on page 46.
Frame error
AP5.4 AP5.6
¯ With mounted and connected I/O board only.
P See parameter Frame error on page 46.
Serial Port Mode
AP5.4 AP5.6
¯ With mounted and connected I/O board only.
Setting of the serial interface type.
RS232 Sets Com2 to RS232.
Data synchronisation may be done by hardware (RTS/CTS) or by software
(XON/XOFF). Maximum cable length is 15m.
RS422 Sets Com2 to RS422.
RS422 is a 4 wire point to point connection, suitable for only one device.
Receiver and driver of the printer are always enabled. Data synchronization
is only possible by software (XON/XOFF). Maximum cable length is 1km with
twisted telecommunication cable.
RS485 Sets Com2 to RS485.
RS485 is a 2 or 4 wire bus system for up to 30 devices. The printer´s receiver
is always enabled, the printer´s driver is only enabled, if the printer sends
data to the host. Data synchronization is only possible by software (XON/
XOFF). Maximum cable length is 1km with twisted telecommunication cable.