03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP5.4 Gen II – AP5.6
52
SYSTEM PARAMETERS
Foil end warning
AP5.4 AP5.6
Setting of a limit diameter for the ribbon roll. If the ribbon roll diameter falls
below the set value, the displayed message changes from…
P For details refer to the parameters DP INTERFACE > Ribbon signal and
SERVICE DATA > OPERATION DATA > Foil diameter
x.xx mm Setting range: 25.4 to 50.0 mm; Unit interval: 0.1 mm;
Default setting: 25.4 mm
Foil warn stop
AP5.4 AP5.6
Disabled (Default setting) Printer does not stop in case of a „Foil end warning“.
Enabled If a „Foil end warning“ occurs, the printer stops after the current label and
shows the status message:
« Press the online button to acknowledge the message, then the feed button to
continue printing.
Print Interpret.
AP5.4 AP5.6
The printer uses the MONARCH LANGUAGE INTERPRETER™ to inter-
prete and process data.
Easyplug Printjobs written in the Easy-Plug command language can be interpreted.
Lineprinter Lineprinter (or similar to Lineprinter), print-out of the print command.
Hex Dump Print-out in hexadecimal format.
In Lineprinter and Hex Dump, commands are printed out in the form of a list
with the character set 12.
¯ When setting Lineprinter or Hex Dump, Easy Plug commands which have
not yet been processed are deleted!
MLI Printjobs written in the ZPL II®
1)
command language can be interpreted.
¯ Firmware loading requires changing into EasyPlug first.
ONLINE X JOBS …to…
FOLIE X JOBS …while the display is blinking.
PrintStatus: 5110
Foil low