03/10 Rev. 5.05-00 USER- / SERVICE MANUAL Info-Printouts & Parameters
AP5.4 Gen II – AP5.6
93
Send test
AP5.4 AP5.6
Serial connection
Carrying out the send test requires a terminal program, e.g. the Hyper Termi-
nal contained in Windows95.
Start send test as follows:
1. Start the terminal program and set it to the transmission parameters used by
the printer.
2. Press the Online-key to start the send test.
[18] Pattern in the terminal window.
The terminal window should show a regular pattern of four repeating charac-
ters. Those characters are continuous sent by the printer.
A transfer fault would be recognizable as irregularity of the pattern. Press the
Prog-key to stop testing.
Send test
running . . .