272 Symbol set (code page) in the System Setup packet must be
0 (Internal), 1 (ANSI), 2 (DOS 437), 3 (DOS 850), 4 (1250- Latin 2), 5 (1251- Cyrillic),
6 (1252- Latin 1), 7 (1253- Greek), 8 (1254- Turkish), 9 (1255- Hebrew), 10 (1256-
Arabic), 11 (1257- Baltic), 12 (1258- Vietnamese), 13 (852- Latin 2), 14 (855-
Russian), 15 (857- IBM Turkish), 16 (860- DOS Portuguese), or 19 (Unicode).
282
RS232 Trailer string is too long. Use a maximum of 3 characters.
283
ENQ Trailer string is too long. Use a maximum of 3 characters.
284
The buffer type must be D (Downloadable Fonts), F (Format), I (Image), R (Receive),
T (Transmit), or V (Scalable Fonts).
285
The storage device type in the memory configuration packet must be R (volatile RAM).
286 The buffer size is invalid.
287
The printhead width must be 0.
290
Action must be 0 (disable) or 1 (enable) for the backfeed control packet or the printer
is active.
291
Dispense position must be 0, or the printer is active.
292
Backfeed distance must be 0 or the printer is active. The backfeed distance can not
be greater than the dispense position.
Check Digit Errors
Error
Code
Description
310
Check digit scheme number must be 1 to 10.
311
Modulus must be 2 to11.
314
Check digit algorithm must be D (sum of digits) or P (sum of products).
Graphic Errors
Error
Code
Description
325
Duplicating direction must be 0 (insert after) or 1 (insert before) in duplicate fields for
graphics.
327
Amount of row adjustment must be 0 to 999 dots in duplicate fields for graphics.
328
Duplicate count must be 0 to 999.
340
Bitmap line encoding must be H (hex) or R (run length).
350
Font selector must be 1 to 9999.
351
Font data length must be 68 to 16384.
352 Insufficient font memory is available for the downloaded font.
DIAGNOSTICS AND ERRORS 8-9