Troubleshooting 4-5
The third label shows network parameters
when the printer is connected to the network.
When the printer is not connected, zeros print
instead of parameters.
4. To resume normal printing, turn off the printer,
wait two seconds, then turn it back on again.
Calibrating the Supply
To calibrate the supply:
1. Turn off the printer.
2. Press and hold the FEED button while turning on
the printer.
3. Release the FEED button after the indicator light
starts flashing ORANGE. The printer calibrates
the black mark or die cut sensor, measures the
label length, and prints the test labels.
4. To resume normal printing, turn off the printer,
wait two seconds, then turn it back on again.