EasyManua.ls Logo

Avery Dennison Pathfinder 6140 - Defining the Interleaved 2 Of5 Options Tag (Optional)

Avery Dennison Pathfinder 6140
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Defining Bar Code Options 4-5
Defining the Interleaved 2of5 Options Tag (Optional)
Use the Options tag to define Interleaved 2of5-specific information.
Valid values include: a 32-bit unsigned decimal number.
It contains the following attributes: density, narrowbar, widebar, and barrierbar.
Syntax <Options density=”value” narrowbar=”value” widebar=”value”
barrierbar=”value” />
density Bar code density. Options: 1 to 13 as shown below. The default is 12.
Density
Selector
Density
(% or cpi)
Narrow Element Width
in Dots/Mils
Narrow to Wide
Ratio
1
1.1
21 / 103.4
1:3.0
2
2.1
12 / 59.1
1:2.5
3
3.2
7 / 34.5
1:3.0
4
4.2
6 / 29.6
1:2.5
5
5.6
4 / 19.7
1:3.0
6
6.3
4 / 19.7
1:2.5
7
7.5
3 / 14.8
1:3.0
8
8.8
3 / 14.8
1:2.3
9
9.6
3 / 14.8
1:2.0
10
11.2
2 / 9.9
1:3.0
11
11.0
2 / 9.9
1:3.0
12
12.7
2 / 9.9
1:2.5
13
14.5
2 / 9.9
1:2.0
narrowbar
widebar
Use the density table above. Using a non-standard value may produce
unreadable bar codes. Define in Pixels.
barrierbar Print a barrier bar (border lines at the top and bottom of the bar code). The
default is disabled (does not print a barrier bar). Options:
0 Disable
1 Enable (print a barrier bar)
Example <Options density=”8” barrierbar=”1” />
Creates an I 2of5 bar code with a density of 8 and prints a barrier bar.

Table of Contents

Other manuals for Avery Dennison Pathfinder 6140

Related product manuals