50 Cyclades ACS 5000 Installation/Administration/User Guide
6. Click apply changes.
Expert - Network - SNMP
An administrator can select Expert - Network - SNMP to configure notifications about significant
events and traps to be sent from the console server to an SNMP management application, such as
HP
®
Openview, Novell
®
NMS, IBM
®
NetView
®
or Sun
®
Net Manager.
When an administrator clicks the Add and Edit buttons under SNMPv1/SNMPv2 Configuration,
the New/Mod SNMP v1 v2 Configuration dialog box appears.
Figure 7.2: Expert - New/Mod SNMP v1 v2 Configuration Dialog Box
Table 7.3: Expert - Fields and Menu Options for SNMP Configuration
Field
or Menu Option Description
SysContact Email address of the console server’s administrator, for example,
acs5000_admin@avocent.com.
SysLocation Physical location of the console server. Default is Cyclades_ACS_5000.
Community SNMP v1 and v2 only. A community defines an access environment. The
type of access is classified under Permission: either read only or read
write. The most common community is public.
NOTE: Use of a public community name is discouraged because it is
commonly known. By default, the public community cannot access SNMP
information on the console server.
Source SNMP v1 and v2 only. Valid entries are default or a subnet address, for
example, 193.168.44.0/24.
OID Object Identifier. Each managed object has a unique identifier.
Permission Read Only or Read/Write access to the entire MIB except for SNMP
configuration objects.
User Name and Password SNMP v3 only.