AXISC15Series
Additionalsettings
Tolearnmore,checkoutourguideGetstartedwithrulesforevents.
Sendanemailifaspeakertestfails
Inthisexampletheaudiodeviceisconguredtosendanemailtoadenedrecipientwhenaspeakertestfails.Thespeakertest
isconguredtobeperformed18:00everyday.
1.Setupascheduleforthespeakertest:
1.1Gotothedeviceinterface>System>Events>Schedules.
1.2Createaschedulethatstartsat18:00andendsat18:01everyday.Nameit"Dailyat6pm".
2.Createanemailrecipient:
2.1Gotothedeviceinterface>System>Events>Recipients.
2.2ClickAddrecipient.
2.3Nametherecipient"Speakertestrecipients"
2.4UnderType,selectEmail.
2.5UnderSendemailto,entertheemailaddressesoftherecipients.Usecommastoseparatemultipleaddresses.
2.6Enterthedetailsfortheemailaccountofthesender.
2.7ClickTesttosendatestemail.
Note
Someemailprovidershavesecurityltersthatpreventusersfromreceivingorviewinglargeattachments,from
receivingscheduledemailsandsimilar.Checktheemailprovider’ssecuritypolicytoavoiddeliveryproblemsand
lockedemailaccounts.
2.8ClickSave.
3.Setuptheautomatedspeakertest:
3.1Gotothedeviceinterface>System>Events>Rules.
3.2ClickAddarule.
3.3Enteranamefortherule.
3.4UnderCondition,selectScheduleandselectfromthetriggerlist
3.5UnderSchedule,selectyourschedule(“Dailyat6pm”).
3.6UnderAction,selectRunautomaticspeakertest.
3.7ClickSave.
4.Setuptheconditionforsendinganemailwhenthespeakertestfails:
4.1Gotothedeviceinterface>System>Events>Rules.
4.2ClickAddarule.
4.3Enteranamefortherule.
4.4UnderCondition,selectSpeakertestresult.
4.5UnderSpeakerteststatus,selectDidn’tpassthetest.
4.6UnderAction,selectSendnoticationtoemail.