Heat exchanger made of PVC & Titanium tube resistant to pool water.
Unit can be installed outdoors.
Features rotary/scroll compressor and low-noise fan motor.
Micro-computer control, parameter setting, LCD display, remote option.
Safety precautions for operation, storage, and electrical connections.
Important safety advice regarding repairs, children, earthing, and specific directives.
Technical specifications and performance data for different models.
Detailed dimensional drawings for different models.
Diagram showing the unit's connection to the pool system.
Guidelines for optimal placement of the heat pump unit outdoors.
Recommendations on the distance of the heat pump from the swimming pool.
Details on connecting the unit to the pool's plumbing system.
Instructions for safe and correct electrical connections.
Step-by-step procedure for the first-time operation of the unit.
Explanation of the icons and display elements on the control panel.
Details on the function of each key and icon on the controller.
Explains the meaning of various symbols displayed on the unit's interface.
Procedure for starting up and shutting down the heat pump unit.
How to change operating modes (cooling, heating, automatic).
Instructions for adjusting the desired water temperature.
Steps for setting the unit's internal clock.
Guide to setting and disabling the unit's timer functions.
Detailed steps for configuring timer ON/OFF settings.
Instructions on how to disable programmed timer settings.
How to activate or deactivate the unit's silent operation mode.
Detailed procedure for managing the silent mode settings.
How to lock and unlock the control panel to prevent unauthorized use.
Explains how fault codes are displayed and interpreted.
Lists fault codes, reasons, and elimination methods for electronic control issues.
Lists default and adjustable parameters for temperature settings.
Diagram and definition of the main board's controller interface.
Explanation of input/output interfaces and their meanings on the main board.
Guidelines for checking the installation area for safety and cleanliness.
Procedures for detecting refrigerant leaks using detectors.
Requirement to have fire extinguishing equipment available.
Precautions against ignition sources during maintenance.
Importance of adequate ventilation during maintenance.
Checks for electrical components and refrigeration equipment integrity.
Procedures for inspecting and maintaining electrical components.
Includes capacitor discharge, live component checks, and earth bonding.
Procedures for repairing sealed components with safety considerations.
Guidelines for working on intrinsically safe components.
Checking cabling for wear, corrosion, and environmental effects.
Methods for detecting refrigerant leaks safely.
Acceptable methods for detecting refrigerant leaks.
Procedures for removing and evacuating refrigerant from the system.
Requirements for labelling de-commissioned equipment.
Procedures for safely recovering refrigerant during servicing or decommissioning.
Step-by-step guide for safely decommissioning the unit.
Requirements and precautions for charging the system with refrigerant.
Tables detailing cable sizes, MCB, and creepage protectors for single/three phase units.
Compares saturation temperatures for R410A and R32 refrigerants.