TOOLS
NEEDED:
3/32”, 1/8” & 7/64” Allen Wrench
Waterproof Wire Connectors
Sleeve or Wedge Anchors for Concrete (1/4” Dia. Min.)
7/16” Socket
Yukon Bollard
Warning High Voltage
Installation Instructions
Product must be installed by a qualified person in a manner
consistent with its intended use and in compliance with the
National Electrical Code, Canadian Electrical Code, and all
Local and Provincial Codes.
Follow product label information and instructions.
Qualified Personnel must perform all servicing or relamping
of this product.
Before wiring to power supply and during servicing or
relamping, turn off power at fuse or circuit breaker before
service.
The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause
an unsafe condition. The use of damaged components may
cause an unsafe condition and void product warranty.
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL
SAFETY AND INSTALLATION INSTRUCTIONS
Do not block light emanating from product in whole or
part, as this may cause an unsafe condition.
Never operate the fixture with missing or damaged lens.
Lens must be cleaned on regular basis.
Entire fixture may become extremely hot. Do not touch hot
lens or fixture body. Do not touch the lamp at any time.
Use a clean, dry, soft cloth to handle the lamp. Oil from
skin may damage the lamp and cause it to rupture.
Replace lamp only with correct wattage and type of lamp
marked on fixture label.
All gaskets, o-rings and sealing surfaces must be kept
clean during installation and service; failure to do this may
cause an unsafe condition and void product warranty.
INSTRUCTIONS PERTAINING TO
A RISK OF FIRE, OR INJURY
TO PERSONS IMPORTANT
SAFETY INSTRUCTIONS
Lighted fixture is HOT!
WARNING - To reduce the risk of
FIRE OR INJURY TO PERSONS:
Turn off/unplug and allow to cool before replacing LED.
Fixture gets HOT quickly! Contact only switch/plug when
turning on. Do not touch hot lens, guard, or enclosure.
Keep fixture away from materials that may burn.
Do not operate the luminaire fitting with a missing or
damaged shield. Do not touch the source at any time.
SAVE THESE INSTRUCTIONS
· Suitable for wet locations
IMPORTANT LISTINGS AND CERTIFICATIONS
CONCRETE INSTALLATION ONLY
RELEASED DATE
09/03/2021
REFERENCE NUMBER
INS-2850-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • info@bklighting.com
B-K LIGHTING
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR
SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.
RE2/RE2: Dual - GFCI w/USB
RE1/RE1: Dual - GFCI
Avaiable Configuration:
Machined
Aluminum
Housing
RE1/RE2: Dual - GFCI & GFCI w/ USB
IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION
INSTRUCTIONS
Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/collaterals/install/digit.
pdf for more information.
Question and Answer IconNeed help?

Do you have a question about the B-K lighting Yukon Bollard and is the answer not in the manual?

Overview

The Yukon Bollard is an outdoor lighting fixture designed for ground-level installation, primarily in concrete. It features a robust machined aluminum housing, ensuring durability and resistance to environmental elements. The bollard is suitable for wet locations, making it ideal for various outdoor settings.

Function Description:

The Yukon Bollard serves as an outdoor lighting solution, providing illumination for pathways, landscapes, and other exterior areas. It can be configured with different wiring options, including incandescent (INC) and 0-10V dimming, to suit various lighting control needs. Additionally, some configurations include integrated GFCI (Ground Fault Circuit Interrupter) receptacles, with or without USB charging ports, offering convenient power access for outdoor tools or devices. The fixture is designed for concrete installation, with a specific anchor kit and base assembly to ensure secure and stable mounting.

Important Technical Specifications:

  • Tools Needed for Installation:
    • 3/32", 1/8", and 7/64" Allen Wrench
    • Waterproof Wire Connectors
    • Sleeve or Wedge Anchors for Concrete (1/4" Dia. Min.)
    • 7/16" Socket
  • Housing Material: Machined Aluminum
  • Wiring Configurations:
    • INC (Incandescent): Standard line, common, and ground connections.
    • 0-10V Dimming: Includes line, common, positive dim, negative dim, and ground connections for dimmable applications.
    • Receptacle: Dedicated line, common, and ground connections for GFCI or GFCI with USB receptacles.
  • Available Configurations (Receptacle Options):
    • RE1/RE1: Dual - GFCI
    • RE2/RE2: Dual - GFCI w/USB
    • RE1/RE2: Dual - GFCI & GFCI w/USB
  • Installation Type: Concrete installation only.
  • Anchor Kit: YKB Anchor Kit, requiring four 1/4-20 nuts for securing the base.
  • Conduit Requirements: Conduit must be run inside the anchor plate center hole prior to pouring concrete.
  • Electrical Sealing: Requires waterproof silicone sealant (not included) as per NEC guidelines.
  • Listings and Certifications: Suitable for wet locations, cULus listed.

Usage Features:

  • Versatile Lighting Control: Supports both standard incandescent wiring and 0-10V dimming, allowing for flexible light output adjustments.
  • Integrated Power Access: Select models offer GFCI receptacles, with options for USB charging, providing convenient outdoor power for various applications without needing separate outlets.
  • Durable Construction: The machined aluminum housing ensures longevity and resistance to harsh outdoor conditions.
  • Secure Mounting: Designed for concrete installation with a dedicated anchor kit, providing a stable and robust fixture.
  • Easy Wiring Access: The base assembly allows for primary branch circuit wiring and dimming controls to be pulled through and connected within the housing.
  • Receptacle Cover: If equipped with a receptacle, it includes a cover secured by a set screw for protection.

Maintenance Features:

  • LED Replacement: The manual advises turning off/unplugging the fixture and allowing it to cool before replacing the LED.
  • Lens Cleaning: The lens must be cleaned on a regular basis to maintain optimal light output and prevent unsafe conditions.
  • Gasket and Sealing Surface Maintenance: All gaskets, o-rings, and sealing surfaces must be kept clean during installation and service to prevent unsafe conditions and void product warranty.
  • Component Replacement: Qualified personnel must perform all servicing or relamping. The use of damaged components may cause unsafe conditions and void the product warranty.
  • Safety Precautions:
    • Always turn off power at the fuse or circuit breaker before wiring or servicing.
    • Avoid touching hot lens, guard, enclosure, or the light source itself, as the fixture gets hot quickly.
    • Do not operate the luminaire with a missing or damaged shield/lens.
    • Keep the fixture away from materials that may burn.
    • Handle lamps with a clean, dry, soft cloth to prevent damage from skin oils.
  • Soil Preparation: Proper soil preparation is recommended before installation, with reference to the DIG-IT guide for detailed instructions. This ensures a stable foundation for the concrete pour.

B-K lighting Yukon Bollard Specifications

General IconGeneral
BrandB-K lighting
ModelYukon Bollard
CategoryOutdoor Light
LanguageEnglish