Standard When the needle bar rises 2.9 to 3.3 mm from its
lowest position, the rotary hook point aligns with the
right side of needle.
1. Go to the test mode #4 and move the
needle bar to the left.
2. Turn off the machine.
3. Turn the pulley until the needle meets the
rotary hook point.
4. Check the 2 screws (#1), then turn the pulley
and loosen them.
5. Lower the needle bar to its lowest position.
6. Raise the needle bar 2.9 mm to 3.3 mm.
7. Loosen the screw (#2).
8. Turn the outer rotary hook by hand until
the rotary hook point aligns with the right
side of needle.
9. After adjustment, tighten the 3 screws.
#1
#2
#1
2.9-3.3mm
Needle Bar Rising (Outer rotary hook timing)
May use Upper Pulley
on latest machines