Standard Front - rear clearance between the needle and the edge
of needle plate hole is the same at the left and right.
1. Go to the test mode #4 and move the needle bar to the left and right
to check the clearance.
2. Loosen the screw (#1) .
3. Move the needle holder shaft block (#2)
to the left and right to adjust the clearance.
4. Tighten the screw (#1).
#1
#2
May use test
mode 5
for this
adjustment
Left/Right Needle Clearance
47