GEMINI PLUS II
®
WHIRLPOOL BATH PUMPS
OWNER’S AND OPERATOR’S MANUAL
MODELS ARE UL RECOGNIZED
1795 AND / OR CSA (CUL)
CERTIFIED WHERE APPLICABLE.
CHECK PUMP NAMEPLATE
OR CONSULT FACTORY FOR
SPECIFIC APPROVALS.
PLEASE FILL IN INFORMATION FROM
PUMP NAMEPLATE
PUMP MODEL __________________________
SPEC NUMBER _________________________
DATE CODE ____________________________
TUB MANUFACTURER __________________
6012400 Rev C November 2, 2009
SAVE THESE INSTRUCTIONS -- FAILURE TO FOLLOW INSTRUCTIONS
MAY RESULT IN PERSONAL INJURY, DEATH OR PROPERTY DAMAGE.
NR Regular discharge
A Airswitch
-C Power Cord with Plug
-CJ Power Cord with JJ Plug

Questions and Answers

  • H
    hailey83Jul 30, 2025
    What to do if my Balboa Water Group GEMINI PLUS II is not pumping properly?
    • C
      Chris GriffinJul 30, 2025
      If your Balboa Water Group Water Pump isn't pumping properly, here are a few things to check: * Make sure the jets are pointed away from the suction inlet to prevent air from being forced into the pump suction. * Check if the in-tub suction inlet is blocked or covered. * Inspect the pump housing for any debris. * Look for any leaks in the piping or the pump itself. * Verify there's no pipe glue in the pump end. * Ensure the proper voltage is applied to the pump. If low voltage is the issue, check this. * Avoid using an extension cord.
  • P
    Paul BurtonAug 13, 2025
    How to troubleshoot a Balboa Water Group GEMINI PLUS II that does not run?
    • K
      Kenneth JonesAug 13, 2025
      If your Balboa Water Group Water Pump isn't running, consider the following troubleshooting steps: * Check the incoming power to the pump. * Ensure the circuit breaker is on. * Verify the GFCI is operating properly. * Confirm the pump is plugged in. * Check if the airswitch hose is connected to the pump. * Ensure the airswitch hose is connected to the actuator button on the tub deck.

Summary

Important Safety Instructions

General Safety Precautions

Basic safety precautions for electrical equipment installation and use, including supervision and application limitations.

General Information

Intended Use and Testing

Pump designed for Hydromassage Bathtub indoor applications; tested prior to factory shipment.

Installation Instructions

Pump Mounting and Piping

Install pump outside bathing area, ensure continuous rise for air expulsion, and secure mounting.

Union Connector Installation

Connect piping using union connectors; hand-tighten nuts only to prevent damage.

Wiring Instructions

Electrical Connection Requirements

Requires licensed electrician, correct voltage, GFCI protection, and proper wire sizing.

Bonding Connector Requirement

Connect bonding connector to all metal parts of the whirlpool bath structure.

Basic Operation and Maintenance

Starting and Stopping the Pump

Ensure power supply, fill tub, and operate via airswitch, keypad, or timer.

Maintenance and Precautions

No pump maintenance needed; check for leaks, avoid running dry, and prevent freezing.

Trouble Shooting Guide

Pump Not Running or Pumping Properly

Check power, GFCI, connections, airswitch, blockages, leaks, and voltage.