Balluff Network Interface EtherCAT
www.balluff.com
10
4 Technical data
Port
Standard port
Status
Function
off
Status of input or output pin is 0
Yellow
Status of input or output pin is 1
Both LEDs red flashing
Sensor power supply short circuit between pin 1 and pin 3
Red
Short circuit at the output on pin 2 / 4 to pin 3
IO-Link port
Status
Function
Green
IO-Link connection active
Green, flashing
No IO-Link connection
Green, rapid flashing
IO-Link preoperate during the data management
Red, rapid flashing
Validation failed / incorrect configuration of the IO-Link data
length
Red, rapid flashing
Data management failed / incorrect device for data management
Red
IO-Link short circuit pin 4 to pin 3