5 Configuration: "Extension Off"
Inversion of the
inputs 40
hex
Byte 0
Bit 7 6 5 4 3 2 1 0
Sub-
index
8 7 6 5 4 3 2 1
Description
Inversion Port 7 Pin 4
Inversion Port 6 Pin 4
Inversion Port 5 Pin 4
Inversion Port 4 Pin 4
Inversion Port 3 Pin 4
Inversion Port 2 Pin 4
Inversion Port 1 Pin 4
Inversion Port 0 Pin 4
Inversion port (x):
0 Normal
1 Inverted.
Configuration
In-Outputs 41
hex
Byte 0
Bit 7 6 5 4 3 2 1 0
Sub
Index
8 7 6 5 4 3 2 1
Description
Direction
Port 7 Pin 4
Direction
Port 6 Pin 4
Direction
Port 5 Pin 4
Direction
Port 4 Pin 4
Direction
Port 3 Pin 4
Direction
Port 2 Pin 4
Direction
Port 1 Pin 4
Direction
Port 0 Pin 4
Direction port (x):
0 Input
1 Output
Safe state of
Outputs 42
hex
The safe state parameter makes it possible to configure the outputs in case of a fault. If no
IO-Link communication is possible or the "valid flag" of the output process data has not been
set by the master, then each output adopts the configured status. The following statuses can
be configured for each pin.
Byte 0 1
Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
Sub-
index
4 3 2 1 8 7 6 5
Description
Safe state Port 3 Pin 4
Safe state Port 2 Pin 4
Safe state
Port 1 Pin 4
Safe state Port 0 Pin 4
Safe state Port 7 Pin 4
Safe state Port 6 Pin 4
Safe state Port 5 Pin 4
Safe state Port 4 Pin 4

Table of Contents