EasyManua.ls Logo

Balluff BNI IOL-309-002-Z019 - Voltage monitoring 44 hex; Monitoring the outputs 45 hex

Balluff BNI IOL-309-002-Z019
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Balluff Network Interface / IO-Link BNI IOL-309-002-Z019
www.balluff.com
14
5 Configuration: "Extension Off"
Voltage
monitoring
44
hex
Byte 0 1
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Sub-
index
8 7 6 5 4 3 2 1 16 11 9
Description
Short
-
circuit Port 7 Pin 1
Short
-
circuit Port 6 Pin 1
Short
-
circuit Port 5 Pin 1
Short
-
circuit Port 4 Pin 1
Short
-
circuit Port 3 Pin 1
Short
-
circuit Port 2 Pin 1
Short
-
circuit Port 1 Pin 1
Short
-
circuit Port 0 Pin 1
-
-
-
-
Outputs off (UA too
low)
Undervoltage UA
-
Undervoltage US
Monitoring
the outputs
45
hex
Byte 0
Bit
7
6
5
4
3
2
1
0
Sub-
index
8 7 6 5 4 3 2 1
Description
Short
-
circuit Port 7 Pin 4
Short
-
circuit Port 6 Pin 4
Short
-
circuit Port 5 Pin 4
Short
-
circuit Port 4 Pin 4
Short
-
circuit Port 3 Pin 4
Short
-
circuit Port 2 Pin 4
Short
-
circuit Port 1 Pin 4
Short
-
circuit Port 0 Pin 4

Table of Contents