Balluff Network Interface / IO-Link BNI IOL-309-002-Z019
www.balluff.com
20
6 Configuration: extended with BNI IOL-102-002-Z019
Voltage
monitoring
44
hex
Byte 0 1
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Sub-
index
8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9
Description
Short
-
circuit Port 7 Pin 1
Short
-
circuit Port 6 Pin 1
Short
-
circuit Port 5 Pin 1
Short
-
circuit Port 4 Pin 1
Short
-
circuit Port 3 Pin 1
Short
-
circuit Port 2 Pin 1
Short
-
circuit Port 1 Pin 1
Short
-
circuit Port 0 Pin 1
-
-
-
-
Outputs off (UA too
low)
Undervoltage UA
-
Undervoltage US
Byte 2 3
Bit
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Sub-
index
24 23 22 21 20 19 18 17 32 31 30 29 28 27 26 25
Extension port
Description
Short
-
circuit Port 7 Pin 1
Short
-
circuit Port 6 Pin 1
Short
-
circuit Port 5
Pin 1
Short
-
circuit Port 4 Pin 1
Short
-
circuit Port 3 Pin 1
Short
-
circuit Port 2 Pin 1
Short
-
circuit Port 1 Pin 1
Short
-
circuit Port 0 Pin 1
-
-
-
-
-
Undervoltage UA
-
Undervoltage US
Monitoring the
outputs 45
hex
Byte 0
Bit 7 6 5 4 3 2 1 0
Sub-
index
8 7 6 5 4 3 2 1
Description
-
Short
-
circuit Port 6 Pin 4
Short
-
circuit Port 5 Pin 4
Short
-
circuit Port 4 Pin 4
Short
-
circuit Port 3 Pin 4
Short
-
circuit Port 2 Pin 4
Short
-
circuit Port 1 Pin 4
Short
-
circuit Port 0 Pin 4
Setting the
serial number
54
hex
The serial number has a default value of 16x00
hex
.
In order to use the "Identity" master validation mode, a serial number can be set using this
parameter.
This prevents a device from connecting to the wrong master port.