Resetting all values (reset)
NOTICE!
Interference in function
Resetting the values while the system is running may
result in malfunctions.
Stop the system before performing the reset.
The reset function can be used to restore all the settings
to the factory settings. For a reset the magnet may also be
located outside the measuring range.
Displayed values (example)
At 0…10 V At 4…20 mA
5.39 V 9.15 mA
Activate reset
Simultaneously activate
a
and
b
for at least 4s.
>4s
a
b
10.50 V 3.60 mA
Reset
Simultaneously activate
a
and
b
for at least 4s.
>4s
a
b
0.00 V 4.00 mA
After activation:
All values are reset.
9.89 V 19.13 mA
Current position value is displayed.
Reset is deactivated.
Abort reset
Resetting can be aborted without any changes
being saved after the Activate reset step.
Briefly activate
a
and
b
simultaneously (< 1s).
<1s
Current position value is displayed.