BSG TID-05-T30-01-005
11
4 The Easy Tool-ID System
4.7. Usage
The Easy Tool-ID system can be used once it is provided with power and connected to the
HMI via USB. To do so, place a tool with RFID data carrier into the tool holder.
Note
Make sure that the tool has been put in the holder correctly. The RFID tag should
now be right in front of the read/write head. That ensures secure data transmission.
After selecting the tool's position, the user presses the button on the front side of the tool
stand. Then the data on the data carrier is read out and forwarded to the HMI. After a short
processing time (about 2 s), the system begins outputting the contents in the HMI.
Caution
To ensure the data is written correctly, the HMI must not be manually controlled
during the write operation. In addition, the system has to be located at the correct
input site. If the system is used in an environment for which it has not been
configured, this will lead to incorrect input in the HMI!
Once the data has been transmitted to the HMI, you can take the tool out of the tool holder
and put it in its intended location. Now you can continue with the next tool in the same way.
Canceling a process
If you want to cancel the current write operation, press and hold the button during the output
until the green LED starts flashing in the rhythm "long on short off long on". The write
operation stops immediately.