This reecve surface may result from shiny surfaces or glossy paint on the machine, the workpiece, the work surface, the oor, or the walls. Beams
deected by reecve surfaces are discovered by performing the trip test and the periodic checkout procedures. To eliminate problem reecons:
• If possible, relocate the sensors to move the beams away from the reecve surface(s), being careful to maintain adequate separaon distance
• Otherwise, if possible, paint, mask, or roughen the shiny surface to reduce its reecvity
• Where these are not possible (as with a shiny workpiece or machine frame), determine the worst-case resoluon resulng from the opcal short
circuit and use the corresponding depth penetraon factor (Dpf or C) in the Safety Distance (Minimum Distance) formula; or mount the sensors
in such a way that the receiver's eld of view and/or the emier's spread of light are restricted from the reecve surface
• Repeat the trip test to verify that these changes have eliminated the problem reecon(s). If the workpiece is especially reecve and comes
close to the dened area, perform the trip test with the workpiece in place
Do not position reflective surfaces within the shaded area
Operating Range
(R)
ReceiverEmitter
d
d
For 0.1 to 3 m (4 in to 10 ) Operang range: d = 0.13 m (5 in)
For Operang range > 3 m (> 10 ): d = 0.0437 × R (m or )
Figure 1. Adjacent Reecve Surfaces
Specicaons
See the EZ-SCREEN LS instrucon manual, p/n 179480 on the accompanying CD-ROM, for the complete set of safety light curtain specicaons,
installaon instrucons, applicaon requirements, and guidelines.
Operang
Range
0.1 m to 8.4 m (4 in to 27 )
Resoluon
23 mm
Operang Condions
–20 °C to +55 °C (–4 °F to +131°F)
95% maximum relave humidity (non-condensing)
Safety Rang
Type 4 per IEC 61496-1, -2
Category 4 PL e per EN ISO 13849-1
SIL3 per IEC 61508; SIL CL3 per IEC 62061
PFHd: 3.92 × 10
-10
Eecve Aperture Angle (EAA)
Meets Type 4 requirements per IEC 61496-2, Secon 5.2.9
Output Signal Switching Devices (OSSDs)
Two redundant solid-state 24 V dc, 0.5 A max. sourcing OSSD (Output Signal Switching
Device) safety outputs (Use oponal interface soluons for ac or larger dc loads)
ON-State voltage: > Vin – 1.5 V dc
OFF-State voltage: 0 V dc typical, 1 V dc maximum (no load)
OFF-State, maximum allowed external voltage: 1.5 V dc
2
Maximum load capacitance: 1.0 μF
Maximum cable resistance to load: 5 ohms per wire
Maximum leakage current: 50 μA (with open 0 V)
OSSD test pulse width: 200 μs typical
OSSD test pulse period: 200 ms typical
Switching current: 0 A minimum; 0.5 A maximum (per OSSD)
Shock and Vibraon
Components have passed vibraon and shock tests according to IEC 61496-1
This includes vibraon (10 cycles) of 10-55 Hz at 0.35 mm (0.014 in) single amplitude
(0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles).
Environmental Rang
IEC IP69K per DIN 40050-9; light curtain also rated IP65/IP67 per IEC 60529
Cercaons
2
The maximum voltage allowed on the OSSDs in the OFF-state without a lockout occurring. This voltage may occur, for example, from the input structure of a safety relay module connected to
the EZ-SCREEN LS OSSDs
EZ-SCREEN LS Safety Light Curtain in an IP69K Hygienic Housing
2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 202514 Rev. C