This reecve surface may result from shiny surfaces or glossy paint on the machine, the workpiece, the work surface, the oor, or the walls. Beams
deected by reecve surfaces are discovered by performing the trip test and the periodic checkout procedures. To eliminate problem reecons:
If possible, relocate the sensors to move the beams away from the reecve surface(s), being careful to maintain adequate separaon distance
Otherwise, if possible, paint, mask, or roughen the shiny surface to reduce its reecvity
Where these are not possible (as with a shiny workpiece or machine frame), determine the worst-case resoluon resulng from the opcal short
circuit and use the corresponding depth penetraon factor (Dpf or C) in the Safety Distance (Minimum Distance) formula; or mount the sensors
in such a way that the receiver's eld of view and/or the emier's spread of light are restricted from the reecve surface
Repeat the trip test to verify that these changes have eliminated the problem reecon(s). If the workpiece is especially reecve and comes
close to the dened area, perform the trip test with the workpiece in place
Do not position reflective surfaces within the shaded area
Operating Range
(R)
ReceiverEmitter
d
d
For 0.1 to 3 m (4 in to 10 ) Operang range: d = 0.13 m (5 in)
For Operang range > 3 m (> 10 ): d = 0.0437 × R (m or )
Figure 1. Adjacent Reecve Surfaces
Specicaons
See the EZ-SCREEN LS instrucon manual, p/n 179480 on the accompanying CD-ROM, for the complete set of safety light curtain specicaons,
installaon instrucons, applicaon requirements, and guidelines.
Operang
Range
0.1 m to 8.4 m (4 in to 27 )
Resoluon
23 mm
Operang Condions
–20 °C to +55 °C (–4 °F to +131°F)
95% maximum relave humidity (non-condensing)
Safety Rang
Type 4 per IEC 61496-1, -2
Category 4 PL e per EN ISO 13849-1
SIL3 per IEC 61508; SIL CL3 per IEC 62061
PFHd: 3.92 × 10
-10
Eecve Aperture Angle (EAA)
Meets Type 4 requirements per IEC 61496-2, Secon 5.2.9
Output Signal Switching Devices (OSSDs)
Two redundant solid-state 24 V dc, 0.5 A max. sourcing OSSD (Output Signal Switching
Device) safety outputs (Use oponal interface soluons for ac or larger dc loads)
ON-State voltage: > Vin – 1.5 V dc
OFF-State voltage: 0 V dc typical, 1 V dc maximum (no load)
OFF-State, maximum allowed external voltage: 1.5 V dc
2
Maximum load capacitance: 1.0 μF
Maximum cable resistance to load: 5 ohms per wire
Maximum leakage current: 50 μA (with open 0 V)
OSSD test pulse width: 200 μs typical
OSSD test pulse period: 200 ms typical
Switching current: 0 A minimum; 0.5 A maximum (per OSSD)
Shock and Vibraon
Components have passed vibraon and shock tests according to IEC 61496-1
This includes vibraon (10 cycles) of 10-55 Hz at 0.35 mm (0.014 in) single amplitude
(0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles).
Environmental Rang
IEC IP69K per DIN 40050-9; light curtain also rated IP65/IP67 per IEC 60529
Cercaons
2
The maximum voltage allowed on the OSSDs in the OFF-state without a lockout occurring. This voltage may occur, for example, from the input structure of a safety relay module connected to
the EZ-SCREEN LS OSSDs
EZ-SCREEN LS Safety Light Curtain in an IP69K Hygienic Housing
2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 202514 Rev. C