ProductChange Command Group
Command Group Item Description
Do ProductChange [
Name
] Forces the device to switch to the specified inspection. The device does
not transmit a response until it has completed the action. Inspections
results will be invalid until the next trigger.
Get ProductChange InspectionNames List of all inspections stored in the device.
Examples
>> get productchange inspectionnames\x0D\x0A
<< OK\x0D\x0A
>> do productchange "inspection2"\x0D\x0A
<< OK\x0D\x0A
History Command Group
Command
Group Item Description
Get History Passed Indicates the number of passed inspections for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get History Failed Indicates the number of failed inspections for the active inspection. This
value is cleared (reset) whenever history is cleared. This value is cleared
(reset) when the device starts up or is rebooted.
Get History MissedTriggers Indicates the number of missed triggers for the active inspection. This
value is cleared (reset) whenever history is cleared. This value is cleared
(reset) when the device starts up or is rebooted.
Get History StartFrameNumber Indicates the starting frame number for the active inspection. This value
is cleared (reset) whenever history is cleared. This value is cleared (reset)
when the device starts up or is rebooted.
Get History EndFrameNumber Indicates the latest frame number for the active inspection. This value is
cleared (reset) whenever history is cleared. This value is cleared (reset)
when the device starts up or is rebooted.
Get History TotalFrames Indicates the total number inspections (frames) for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get History MinInspectionTime Indicates the minimum (fastest) inspection time for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get History MaxInspectionTime Indicates the maximum (slowest) inspection time for the active
inspection. This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Get History MinBarcodeCount Indicates the minimum number of barcodes read for the active
inspection This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Get History MaxBarcodeCount Indicates the maximum number of barcodes read for the active
inspection This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Do History Clear Clears all history fields for the active inspection. History values include
pass count, fail count, execution times and sensor specific history
values. This command can be performed using the sensor's
touchscreen.