3. The Memory Device and Master Scanner topologies will not match each other because the Memory Device has no
configuration (empty when new). The Master Scanner's display may show the INTF18 error or MEMORY EMPTY
message. THIS IS A NORMAL BEHAVIOR and expected.
4.
The Memory Device can now be aligned with the Master Scanner topology either with a BACKUP CONFIGURATION
copied from the Master Scanner to the Memory Device (follow the procedure shown on the Master Scanner's display
and described below) or by loading a configuration using the configuration software (see Load a Saved Configuration
to a Scanner on p. 94). Select the desired procedure using the keypad of the Master Scanner.
5. Follow the procedure shown on the Master Scanner's display:
a) Press the square middle button next to the display. The screen should show Backup cfg/Cfg from GUI/Exit.
b) Select Backup cfg by clicking the center button when Backup cfg is highlighted.
c) The display asks Are you sure to run bkp operation? Confirm/Cancel. To select Confirm, make sure it is
highlighted then press the center button. The backup will commence. The display shows BKP IN PROGRESS.
d) After a number of seconds the display will switch to the finished screen before returning to full operation (normal
display based on the environment).
If the backup fails, the display will show BKP FAILED. Retry the backup and if it still fails try a different Memory
Device.
Step 5b. Step 5c. Step 5c.
11.5.2 Fast Replacement of the Master Scanner
Follow these steps to replace the master scanner with an already configured memory device.
1.
Unmount the memory device from the damaged scanner and install it on the new scanner (see Mounting and
Unmounting the Removable Memory on p. 45).
2. Verify that the new memory device is the same model number as the replaced device (must replace a 8 or 12 pin QD
memory device with an 8 or 12 pin QD memory device or a 17 and 8 pin QD memory device with a 17 and 8 pin QD
memory device).
3. If the new scanner (just purchased not re-purposed) and memory device are not compatible, the scanner display
shows the WAITING CONFIG message. If a re-purposed scanner is used and has not been reset to factory default
settings, the scanner display shows the MEMORY DOESN'T MATCH message.
In a configuration with master and remote scanners, only replace the damaged master scanner. Do not change any
remote scanners or the topology of the configuration will be changed. If anything other than the damaged master
scanner is changed, the master device display shows the DEVICD EMPTY or WAITING CONFIG message and a
new configuration must be loaded using the configuration software.
4. The cluster size and models now match and only the serial numbers do not match the original configuration. The
master scanner display shows the CFG NO MATCHING message. The master scanner can now be aligned with the
memory device topology by restoring the configuration from the memory device to the scanner (see next step) or
by loading a configuration using the configuration software (see Load a Saved Configuration to a Scanner on p. 94).
5. To restore the configuration from the memory device, follow these steps:
a) Press the square middle button next to the display. The screen should show Restore cfg/Cfg from GUI/Exit.
b) Select Restore cfg by clicking the center button when Restore cfg is highlighted. The display shows: Are you
sure to run restore operation? Confirm/Cancel.
c) To select Confirm, make sure it is highlighted then press the center button. The restore process will commence.
The display shows RES IN PROCESS.
d) After several seconds, the display switches to the Run Test Mode screen. Press the center button to enter test
mode (and validate the scanner fields) (the display goes dark for a few seconds before returning with the
Configuration not accepted view) or press the down arrow to exit.
e) After validating the safety zones with the new scanner, press the down arrow to accept or reject the validation.
Highlight the desired entry and press the center button. If accepted, after pressing the accept validation, the RES
VALIDATION screen will show for a few seconds before the scanner enters run mode. If reject is selected, the
software must be used to create/load a new configuration.
SX Safety Laser Scanner
124 www.bannerengineering.com - Tel: + 1 888 373 6767