Signal Function Connection
Muting 1 Muting 2
Muting Enable
Multi Out
Warning
Alarm
Muting Lamp
OSSD OSSD 1/1 OSSD 1/2
See Machine Interface Connections for the Stand-alone Models on p. 51.
4.4.3 Machine Interface Connections for the Master (12-pin)
The M10 Master models wired with the 12-pin connector can be configured for one or two OSSD pairs and include five
configurable signals. These five signals allow the user to configure the scanner with different functions. One pin acts only as
an input. The other four pins can act as an input or an output.
Type Signal Pin Color Description 12-pin Male Pinout
Power
Power supply
1 Brown
24 V DC
4 Green
GND_ISO
2 Blue
0 V DC
6 Yellow
Input Multi in 3 White Software Selectable
Input/Output Multi in/out
7 Black
Software Selectable
9 Red
10 Violet
11 Gray/Pink
Safety Output
OSSD 1/1 8 Gray
Safety Output
OSSD 1/2 5 Pink
Other F_Earth 12 Red/Blue Functional Earth
Note: In configurations with remote scanners, both POWER SUPPLY and GND_ISO wires must be
connected. It is recommended to always connect both sets of wires.
The Multi-in pins can be configured as inputs while the Multi in/out pins can be configured either as an input or an output. The
functionality that the Multi in and Multi In/Out can be configured as are as follows:
Type Function Description Circuit
Multi in
RESTART Restarts the device following OSSD off-status
RESET
Restores the device after a fault condition
(like a power cycle)
RESTART 1/RESET Restarts or restores the device
AREA SWITCH 1
Switches the detection areas by employing
external signals
AREA SWITCH 2
AREA SWITCH 3
AREA SWITCH 4
SX Safety Laser Scanner
56 www.bannerengineering.com - Tel: + 1 888 373 6767