9 / 28
Corrosion: loss of explosion protection
The enclosure of the hand-held scanner has protection class IP67, however constant exposure to moisture can lead
to corrosion. This may lead to the loss of the explosion protection.
Protect hand-held scanners against constant exposure to moisture.
Do not subject hand-held scanners to any damp weather conditions.
2.4.2 Damage to eyes caused by laser light
The hand-held scanner operates with a Class 2 laser. Laser beams can damage eyes.
Do not look into the laser beam.
2.4.3 Risks of cuts if the scan window is broken
The scan window may become damaged if the hand-held scanner falls down. There is a risk of cuts if you reach into
the broken or cracked area.
When getting the hand-held scanner out, secure it to prevent it falling down.
Only get the hand-held scanner out when it reaches its destination.
If the scan window is broken:
– Do not touch the broken area.
– Do not use the hand-held scanner.
– Send the faulty hand-held scanner to BARTEC.
2.4.4 Health hazard in the case of incorrect disposal
Lithium ion batteries on the Bluetooth hand-held scanner contain pollutants that can be harmful to health.
Dispose of batteries in an environmentally sound way in accordance with regional regulations.