EasyManua.ls Logo

Barton 95534 - Operation; Leak Test and Ignition; Flame Adjustment and Griddle Use; Post-Extinguishment Procedure

Barton 95534
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
OPERATION
STEP 1: Make sure the wheels are locked to prevent it
from moving during operation.
STEP 2: Hold a lighter near the burner.
Begin the following steps ONLY after performing a leak test and no leaks are detected.
STEP 3: • Light burner; rotate knob(s) from HIGH to LOW. You should see a smaller ame in
LOW position than seen on HIGH. Always check ame prior to each use. The air damper
mounted on the back of your burner helps to control the amount of primary air that mixes with
the LP gas. A blue ame with little or no yellow ame provides the best heat. Adjust the
air damper by turning it clockwise or counterclockwise until the desired ame is achieved.
STEP 4: Place the griddle on top of the cooking surface to cook.
STEP 5: To turn off the stove: Turn all knobs to OFF position. Turn LP tank OFF by turning
handwheel clockwise to a full stop.
NOTE: Before each use, check to see if hoses are cut or worn. Replace damaged hose
assembly before using appliance. Use only valve/ hose / regulator specied by manufacturer.
See product sheet for hose & regulator information.
If the ame is accidentally extinguished, turn the appliance valves OFF and
WAIT 5 minutes before attempting to ignite.