April 26, 2007 Page 9
BAUER
COMPRESSORS
2.3.3 Connecting to the Air Storage Bottle
1. Ensure both the fill valve and bottle valve are closed
2. Connect the air bottle to the compressor fill hose utilizing the fill yoke.
2.3.4 Filling the Bottle
1. First open fill valve. (1)
2. Open bottle valve. (2)
3. Bottle will begin filling.
4. During the filling process, monitor bottle pressure on fill valve gauge and drain condensate at the
compressor.
2.3.5 Removing the Bottle
1. First close the bottle valve. (1)
2. Close the fill valve. (2)
3. Remove fill yoke and store compressed air bottle.
2.4 Shut-Down Procedures
1. On all units first close the fill valve.
2. Turn off electrical power with the appropriate switch
3. Vent unit to approximately 1,150 psi (80 bar).
4. Decompress with drain valves to remove all moisture in the filter and the oil and water separator.
5. Close all drain valves again.
6. Check the oil level in the compressor and top up, if necessary.
7. Also check operating hours to see if the compressor needs servicing in accordance with the mainte-
nance schedule.

Table of Contents