6.4 Cooling System
6.4.1 General
The cylinders of the compressor block, the intermediate coolers, and the after-cooler are all air cooled.
For this purpose the compressor is equipped with a fanwheel connected to the crankshaft at the end
opposite the V-belt pulley. It draws cooling air through the fanwheel cover from the surrounding atmo-
sphere.To ensure maximum compressor unit life, provisions must be made for an adequate supply of
cooling air during installation of the compressor unit. For the same reasons the unit must not be oper-
ated above the maximum ambient temperature.