Page 90 1st Edition, Rev. 0 Chg. 10
7.11.2.4 Four Flashes - Securus
®
Alarm
Investigate or Possible Cause Corrective Action
Securus
®
Cable disconnected Reconnect Securus
®
Cable
Securus
®
Cartridge saturated or expired. Replace all purification system cartridges
7.11.2.5 Five Flashes - Carbon Monoxide Monitor Alarm
Investigate or Possible Cause Corrective Action
Monitor is not operating with proper pressure and flow Adjust as required.
Monitor is not properly calibrated Calibrate Monitor
If above checks are okay
Replace Purifications Cartridges
a
a. A typical source of carbon monoxide is engine exhaust. Ensure compressor intake is from a fresh air source to prevent premature consumption of the purification cartridges.
7.11.2.6 Six Flashes - Final Separator Shutdown
Investigate or Possible Cause Corrective Action
Final Separator has reached maximum number of Pres-
surization Cycles.
Replace Final Separator
7.11.2.7 Seven Flashes -Condensate Fault
Investigate or Possible Cause Corrective Action
Check Condensate Level, if full Drain and properly dispose of Condensate
Tank contents.
Check Condensate Level, if not full Clean switch.
If above checks are okay Replace switch