1.5 Technical Specifications
All technical data is subject to change without prior notice.
Medium Air
Free Air Delivery 7.0 scfm ((198 l/min)
1
Inlet pressure atmospheric
Operating pressure, max. 5,000 psig (350 bar)
Ambient temperature range 41 to 113 °F (5 to 45 °C)
1.5.1 Compressor Block
IK120 II Mod. 7
No. of stages 3
No. of cylinders 3
Cylinder bore, 1st stage 3.46 in. (88 mm)
Cylinder bore, 2nd stage 1.42 in. (36 mm)
Cylinder bore, 3rd stage 0.55 in. (14 mm)
Piston Stroke 1.57 in.(40 mm)
Intermediate pressure, 1st stage 87 - 102 psig (6 - 7 bar)
Safety valve setting, 1st stage 131 psig (9 bar)
Intermediate pressure, 2nd stage 464 -711 psig (40 - 49 bar)
Safety valve setting, 2nd stage 870 psig (60 bar)
Direction of rotation when facing flywheel CCW
Compressor speed 1,385 RPM
Oil capacity 2.96 qts.(2.8 liters)
Oil Pressure 58 - 87 psig (4 - 6 bar)
Recommended oil BAUER OIL-0024
Maximum Inclination 10° in all directions
1.5.2 Compressor Drive Motor
1.5.3 Purification System Applicability
The purification system supplied with this order is the P2 system with the Securus
®
Moisture Monitor-
ing System.
1. Referenced to standard inlet conditions of 68°F and 60% humidity at sea level.
Model Voltage, Phase, Frequency Power RPM Type Part No.
-E3 208-460 VAC, 3Φ, 60 Ηz 7.5 Hp 3,600 ODP MTR-0033