June 11, 2009 Page 45
3.2 Three Stage Automatic Condensate Drain System
3.2.1 Description
The automatic condensate drain system operates electropneumatically and is comprised of the follow-
ing:
An electrically controlled solenoid valve.
A pneumatically operated condensate drain valve
A condensate manifold
A condensate collection system
The automatic condensate drain system drains the intermediate separator and the oil and water separa-
tor every 15 minutes during operation. Additionally the automatic condensate drain system unloads the
compressor during the starting phase and drains these filters at shutdown of the compressor unit.
Figure 3-31 Automatic Condensate Drain
1. Solenoid Valve
2. Blank off Plate
3. ACD Manifold
4. Condensate Drain Valve
5. Manual Condensate Drain
123
4
5