ImVT 120 II Mini Verticus
Page 54 1st Edition, Rev. 0 Chg. 10
CHAPTER 4: IK120 II MAINTENANCE SCHEDULE
4.1 IK120 II Maintenance Intervals
4.1.1 Maintenance Records
We recommend that all maintenance work be recorded, showing the date and details of the work carried
out. This will help to avoid expensive repairs caused by missed maintenance work. If it is necessary to
make a claim against the warranty, it will help to have proof that regular maintenance has been carried out
and that the damage has not been caused by insufficient maintenance.
Interval Maintenance Work
Daily before operating unit
Check Oil Level
Operate unit to final pressure and check final pressure switch
½ hour after maintenance work Check screws and fittings for tightness
500 operating hours
Service micronic intake filter
Check all connections for leakage
1,000 operating hours Valve Check
2,000 operating hours
Change Synthetic Oil and Change Oil Filter
Replace Valves
3,000 operating hours Check pistons and piston rings
Annually
Check opening pressure of final safety valve.
Service micronic intake filter
Biennially Change Synthetic Oil, if operated for less than 2,000 hours
NOTICE
All maintenance intervals refer to normal operating conditions. Operating the compressor under extreme
conditions like high temperatures, humidity or continuous operation may shorten the intervals signifi-
cantly. If in doubt, please contact the Bauer service department.