Page 78 1st Edition, Rev. 0 Chg. 10
7.4.9 Compressor PLC Program Versions
The version of PLC program loaded into your compressor package is denoted with a small white sticker
in the front of the PLC. Please refer to this number when calling Bauer Compressors Product Support.
a. Active Powers PLC program
7.4.10 PLC Inputs and Outputs
All PLC inputs are 24 VDC. The power supply physically exists inside the PLC. All PLC outputs are of
a relay type, and are powered through the control transformer supplying 120 VAC single phase to the
various loads. Please refer to unit schematic for the as built specifications.
Table 7-1: PLC Program Versions
Description 5,000 psi 6,000 psi
Breathing Air Compressor without Unloader v2.45 v2.35
Industrial Compressor Unit with Unloader
a
v2.64 v2.54
Gas Compressor Unit vG1.46 vG1.36
Unicus III with 1 ACD Solenoid vU3.4 vU1.4
Unicus III with 2 ACD Solenoids vU2.4
Industrial Unit with 4 ACD Solenoids v3.1 v3.0