7.8 Overrun Timer
(See Figure 7-13). All versions of the PLC program contain an Overrun Timer that will shut the com-
pressor off after a certain amount of continuous running. The length of time can be set to 5 hours (fac-
tory standard) or from 6 to 24 hours in two hour increments. It can also be bypassed entirely eliminating
the Overrun Timer. Active Powers default setting is “Bypassed
7.8.1 Adjusting the Overrun Timer
(See Figure 7-15). The setting is determined by rotating the Overrun Timer Adjustment.
1. Begin by gently rotating the Overrun Timer Adjustment fully Counter-Clockwise to 9 o’clock. If it
is desired that the compressor shut down after five hours of continuous running, then leave it at this
position.
2. If it is desired that the compressor shut down after six hours or more hours of continuous running,
rotate the Overrun Timer Adjustment Clockwise .
Figure 7-15 Overrun Timer Adjustment
See Figure 7-13 #2 for overrun timer location
NOTICE
The compressor will not operate if the Overrun Timer Adjustment is
rotated fully Clockwise to the 3 o’clock position.
9 o’clock
5 hr. Overrun
then shutdown
11 o’clock
8 hr. Overrun
then shutdown
1 o’clock
bypass overrun
timer
3 o’clock
compressor
will not run