34
Gas
consumption
Power
(kW)
Burner Types
of gas
Pressure
(mbar)
Injector
Marking
(1/100
mm)
g/h l/h Max. Min.
Natural
(G20)
20
72 - 95
Butane
(G30)
30 50 73 -
Auxiliary
Propane
(G31)
37 50 71 -
1.00 0.48
Natural
(G20)
20 97 - 167
Butane
(G30)
30 65 127 -
Semi-
rapid
Propane
(G31)
37 65 125 -
1.75 0.60
Natural
(G20)
20 115 - 286
Butane
(G30)
30 85 254 -
Rapid
Propane
(G31)
37 85 250 -
3.00 1.05
Natural
(G20)
20 135 - 286
Butane
(G30)
30 95 218 -
Wok
Propane
(G31)
37 95 214 -
3.50 1.80
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section on the next page.