o Unscrew the injector (B) and replace it
with the stipulated injector for the new gas
supply (see table below).
GENERAL INJECTORS TABLE
Power (in watts) Kind of gas Nozzle
mm/100
Burners
Max. Min.
Natural 135
115
97
72
Wok
Rapid
Semi-rapid
Auxiliary
3500
3000
1750
1000
1700
700
400
350
L.P.G.
Butane
Propane
95
85
65
50
Wok
Rapid
Semi-rapid
Auxiliary
3500
3000
1750
1000
1700
700
400
350
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.