Procedure of the commissioning
Instruction handbook b maXX (BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06 Baumüller Nürnberg GmbH
46
of 74
8.2
4 Choose submenu „Service“
This window shows the position/slot of the recognized Digital IO module.
If the Digital IO module is available in position/slot D, then the following is displayed:
„Slot D Digital IO 4 Input, 4 Output Version X“.
„X“ shows the version of the module.
5 Decide on the basis of the display.
Figure 11: ProDrive Service
m If the Digital IO module has been correctly recognized, the commissioning can be
continued, refer to Instruction Handbook b
maXX 4000, 5.12008 or Parameter Man-
ual b maXX 4000, 5.03039.
m If the Digital IO module has not been correctly recognized, turn off the device,
check the mounting and the installation. After removing all errors, switch on the de
-
vice again.
m If the Digital IO module has not been correctly recognized again, it is defect or the
controller/controller slot (of standard controller) is defect. Contact Baumüller Nürn
-
berg GmbH for replacement.
6 Icon „ProDrive Navigation“
Digital I/O 16 4 Input, 4 Output
BM4-F-DIO-01/11
Version B