EasyManua.ls Logo

Baumuller B MaXX 4000 Series - Prodrive Service

Baumuller B MaXX 4000 Series
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Procedure of the commissioning
Instruction handbook b maXX (BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06 Baumüller Nürnberg GmbH
46
of 74
8.2
4 Choose submenu „Service“
This window shows the position/slot of the recognized Digital IO module.
If the Digital IO module is available in position/slot D, then the following is displayed:
„Slot D Digital IO 4 Input, 4 Output Version X“.
„X“ shows the version of the module.
5 Decide on the basis of the display.
Figure 11: ProDrive Service
m If the Digital IO module has been correctly recognized, the commissioning can be
continued, refer to Instruction Handbook b
maXX 4000, 5.12008 or Parameter Man-
ual b maXX 4000, 5.03039.
m If the Digital IO module has not been correctly recognized, turn off the device,
check the mounting and the installation. After removing all errors, switch on the de
-
vice again.
m If the Digital IO module has not been correctly recognized again, it is defect or the
controller/controller slot (of standard controller) is defect. Contact Baumüller Nürn
-
berg GmbH for replacement.
6 Icon „ProDrive Navigation“
Digital I/O 16 4 Input, 4 Output
BM4-F-DIO-01/11
Version B
td

Table of Contents