Fault detection
Instruction handbook b maXX (BM4-F-)DIO/FIO-XX (Digital IO module)
Document No. 5.01046.06 Baumüller Nürnberg GmbH
58
of 74
10.2
h Select „Drive management“
The window „Drive manager“ opens, see below with an exemplary (error) message.
Before the communication between controller and PC/laptop is started, the messages in
in this list have been arranged in numerical order. The newly occurring messages are
added to the end of the list, when communication is active.
Figure 19: Drive manager ProDrive
NOTE
If you are not able to start the motor, although the red LED H4 isn’t lighting up and
although the LED H2 is lighting up green, check the parameterization of the
b
maXX 4000 with the parameter list in ProDrive.
Error possibilities are e. g.: torque limit = 0 has been set or notch position is not cor-
rect (also see parameter manual b maXX 4000).
If no LEDs are lighting up on the front side of the device, check the 24V supply.