EasyManua.ls Logo

Baumuller b maXX 5000 Series - Page 316

Baumuller b maXX 5000 Series
330 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connections BM5030 with safety function
Instruction handbook b maXX 5000
Document No.: 5.09021.16 Baumüller Nürnberg GmbH
316
of 328
C.6
Power supply of
the
STO function
For the power supply of the STO function on connector X2 a 24 V power supply unit is
required, which corresponds with the SELV/PELV standards according EN 50178.
Voltage: 24V
DC
-15 %/+20 %
Inputs
STO function
The inputs of connector X2 have been designed according IEC 61131.
The input levels are as follows in case of 24 V DC power supply:
U
Hmax
= 30 V
U
Hmin
= 11 V
U
Lmax
= 5 V
U
Lmin
= -3 V
I
Hmax
= 15 mA
I
Hmin
= 2 mA
I
Lmin
= not determined
I
Lmax
= 15 mA
The maximum length of the cable is 30 m.
The safe inputs are designed for an operation with sensors providing OSSD outputs. The
maximum test
pulse length of 1 ms must not be exceeded.
Both inputs STO A and STO B are necessary for the safety function STO and must be
act
ivated separately. If both inputs are activated by one cable, the fault exclusion short-
circuit according IEC 61800-5-2 appendix D must be considered.
Outputs
BM5030-XX2X-...
Power rating per NO contact: Max. 30 V, max. 100 mA
The maximum cable length is 30 m.

Table of Contents