T 6 Installation
6.16 Connetion data for the terminals
• Mains
Device max. Cable-⊘ Connection technology
BM340X
BM341X
2,5mm
2
Screw connection, provided con-
nectors
BM446X 16mm
2
Screw connection, provided con-
nectors
• 1C1 and 1D1
1)
, Ba+ und Ba-
1)2)
Device max. Cable-⊘ Connection technology
BM340X
BM341X
2,5mm
2
Screw connection, provided con-
nectors
BM446X 16mm
2
Screw connection, provided con-
nectors
1)
not short-circuit proof
2)
Consider maximum load! See chopper resistor external at «Appendix-D Technical data» from page
179.
The load capacity of connections is found in «Appendix D - Technical data» from page 179 under con-
nected load DC-link or motor pow er type at 4kHz. The device is able to brake this power constantly.
• Motor
Device max. Cable-⊘ Connection technology
BM340X
BM341X
2,5mm
2
Screw connection, provided con-
nectors
BM446X 16mm
2
Screw connection, provided con-
nectors
The connection load is automatically limited by the device.