Trouble shooting 8.5T
8.5 Trouble sho oting
The base of error treatment in the b maXX® BM3400 devices are the error messages (see «Error parameters -
Error messages (error list) - Error reactions» from page 138). If there is a fault, additionally to displaying the
error code an according precise error message in WinBASS II is displayed in the menue Drive manager. The
meaning of this message can be looked up in the error list.
NOTE
The device is delivered with predefined error reactions, which can be changed at some errors
(marked in the table). Due to safety reasons errors, which have to have an immediate pulse
inhibit as a consequence are excluded from this possibility to change reactions.
8.5.1 Reset errors
An existent error message can be reset in WinBASS II. At error reset all error messages, which can be reset
under the current error conditions a re reset. An individual error reset is not possible.
There are four methods to reset errors:
• Use the WinBASS II button „Reset errors“ (either in the dialog box „drive manager“ or on page „drive
manager“).
• Enter in the control word parameter P0300 „BM-w-Control word“ with the value (decimal) 128. This
can be made via the parameter list in WinBASS II as well as via field bus.
• I f, under device management, the parameter P1001 „BM-w-D s0-CommSource“ was set to 0 and P1002
„BM-w-Ds0-DrvManagerOptions“ was set to 2 (decimal) or in the WinBASS „Control only with quick-
stop/pulse enable“ and „Reset errors via pulse enable“ was activated, errors are reset by ac tivating the
pulse enable signal.
• Via the parameter P0575 „Digital input for error reset“ a digital input can be selected for error reset.
With the rising edge a t this input the er rors are reset.
Additional data according the subject „Resetting of error messages“ are found in Parameter manual.
Instrution Manual
b maXX
®
BM3400
127
Doument No.: 5.07013.03 from 206