T 8 Error detetion and trouble sho oting
8.5.3 Parameter desription - Warnings (Warning bit list)
AmpWarning (Warning in module power unit) P0262
Warn.-
no.
Mea ning Cause removal
0 Reserved
1–3 Not assigned
4 Mains failure Restore the mains supply
5–15 Not assigned
16 Internal air-temp. > Warning threshold Assure the compliance to the specified
environmental conditions (see «Appendix D -
Technical data» from page 172). Assure a
sufficient ventilation.
17 Heatsink temperature. > Warning
threshold
Reduce the power output, check the fans of the
device
18–19 Not assigned
20 Safety relay off (SR O.K.) but no
voltage)
Check the cabling of the safety relay.
21–23 Not assigned
24 Ixt Value > Limit value1 Take measures, so that the Ixt value does not
exceed 100%.
25–31 Not assigned
MotorWarning (Warning in module motor) P0263
Warn.-
no.
Mea ning Cause removal
32 Motor-temperature > Threshold1 Reduce the power output of the motor.
33 Motor-temperature > Threshold2 Reduce the power output of the motor.
34 I
2
t-value > Limit value1 Reduce the power output of the motor.
35–47 Not assigned
48 Drive not synchronous Check and correct the synchronization
parameter.
49 Serial number changed (controller
PCB replaced)
Contact Baumüller.
50 SW-version changed (unauthorized SW
download)
Contact Baumüller.