T D App endix D - Tehnial data
D.6.1.5 Digital inputs and outputs
Power supply 24V (19V...28V)
Current input max. 500mA
Input voltage 0 ( LOW): 0V(open)...5V
1 ( H IGH): 12V...28V
Input current max. 2mA
Sampling rate DIN1...DIN4 (normal): 2ms
DIN3, DIN4 (quick): 250µs
SH, IF: 4ms
Output current max. 0.6A per channel
Refresh rate 4ms
Short-circuit rating yes, by internal current limit and switch-off at
overtemperature
D.6.1.6 Analog inputs and outputs
Input voltage -10V...+10V
Input resistance 3.5k
Sampling rate 250µs
Output voltage -10V...+10V
Output current max. 10mA
Refresh rate 500µs
Cut-off frequency 1kHz