T D App endix D - Tehnial data
D.6.3 Safety relay (option)
Coil side (X102-3, X102-4)
Rated voltage U
DC
20V
Operating voltage U
DC
15V to 28V
Coil resistance 480 ± 48
Status signal contact (NC contact), (X102-1, X102-2)
Switching voltage U
DC
24V
Switching current I
DC
1mA to 300mA
Max. switch-on frequency 10Hz
Switch-ON delay max. 15ms
Switch-OFF delay max. 12ms
Electrical durability (switch life time) at least 100 000
Mechanical durability (cycles of operation) at least. 5 x 10
7
178