Measures for EMC assurane 6.8T
6.8.4 Mains lter
Devices of housing size b maXX® BM340X resp. b maXX® BM341X are optionaly provided with integrated
mains filter.
If a single b maXX® BM3400 with integrated mains filter is operated, the limits from DIN EN 61800-3 chapter
6.4.2 are observed. Therefor the device can be operated in C3-environments without restrictions.
NOTE
If several b maXX® BM3400 devices with integrated mains filter operate c ombined in a sy stem,
the effect of the integrated filter will be compensated by priciple partially. If these devices
operate without an ad ditional common mains filter, it must be assumed, that limits given in
DIN EN 61800-3 chapter 6.4.2 are exceeded and operation in this way is not allowed.
Because finally the plant manufacturer or carrier is responsible to ensure that the norm is ob-
served, at wa iver of an additional common mains filter the compliance to the limits must be
attested to allow operation of the sy stem in conformity to the norm.