T 6 Installation
6.11 Connetion diagram
Figure 6.10: Connection diagram b maXX® BM3400 at a three-phase supply
X102 Connection of the optional equipable safety relay
X100 Connection 24V-power supply
X202 Mains connection (here triple phase)
X23 Communication interface RS232
X26 Digital inputs (pulse enable, quickstop)
X24/25 Terminals for encoder 1 and encoder 2
X204 Connection for motor
X101 Connection for motor temperature sensor
X205 Connection for ext. chopper resistor or chopper resistor activation
R
b
External chopper resistor
S1 Fuses (circuit cable + device)
Enc Encoder
70
Instrution Manual
b maXX
®
BM3400
from 206 Doument No.: 5.07013.03
Baumueller Kamenz GmbH