T 6 Installation
6.12.1.1 HS0 single phase V1 (BM340X-L1XX-XXXX-O)
Connector Qua ntity Usage Type
X26 2 dig./anal. IO COMBICON FK-MC 0,5/12-ST-2,5
X102 1 safety relay COMBICON MC 1.5/4-ST-3.5
X100 (new) 1 24V-supply COMBICON MC 1.5/6-ST-3.5
X201 (prev.)
1)
X202 1 power input COMBICON MSTB 2.5/3-ST-5.08
1)
X100 (respectively X201) was renamed due to compatibility reasons to the b maXX® BM4400 devices, func-
tion and pin assignment, however, was kept consistent.
X102-4, M24V_R
X102-3, + 24V_R
X102-2, KS_S
X102-1, KS_P
X100-6, -24V
X100-5, -24V
X100-4, B_EIN
X100-3, N_EIN
X100-2, + 24V
X100-1, + 24V
X202-3, PE
X202-2, 1N1
X202-1, 1L1
Figure 6.14: Connections on top at HS0 (single phase supply) for type key V1
74
Instrution Manual
b maXX
®
BM3400
from 206 Doument No.: 5.07013.03
Baumueller Kamenz GmbH